Globus Genesy 3000 Electrostimulator multifunctional

Genesy 3000 ELECTROTHERAPY

This last-generation Professional Electrostimulator was developed  to implement its potential uses in the medical, rehabilitation and physiotherapy fields.

53 Sport – 29 Fitness – 16 Beauty – 11 Rehabilitation – 33 Pain – 23 Microcurrents – 9 Denervated – 9 Interferentials – 1 Ionophoresis – 3 Incontinence – 236 Electrotherapy Menu (Ems – Russian)

It runs on mains supply or battery, therefore it can be used both as a fixed station and as a portable unit.

Leggi la descrizione completa
 

Warranty: 2 years


€999.00
In stock
G1034

Quantity


Globus Genesy 3000 Electrostimulator multifunctional

Use this form to request us information about this product. For more complete answers, please ask detailed questions. Thank You.


  SHIPPING PARTNER

DHL

  SHIPPING PARTNER

DHL

  Monday - Friday:

9.00 - 12.30 | 14.00 - 17.00

Accessories

Check items to add to the cart

Genesy 3000 ELECTROTHERAPY

made in italy

The Genesy 3000 is the spearhead of the new advanced range Globus as it concentrates the best technologies and functions that Globus has developed in recent years.

This second generation advanced electrostimulator is in fact born from a new hardware and software project that has implemented the potential for use in medical, rehabilitative and physiotherapy.

The unit, characterized by a larger size and an ergonomic design, thanks to the network and battery operation, can be used both as a fixed station and as a portable unit.

The Genesy 3000 is the most suitable stimulator for the treatment of pain, for the healing of tissues and for the treatment of neuromuscular dysfunction.

See how to place the Electrodes through the videos on our Youtube channel

The system is designed to allow a more effective and rapid retesting of injured athletes and to reduce, at the same time, the possibility of new injuries.
The programs are specifically designed both to solve the acute post-traumatic phase and to recover athletes who had to undergo reconstructive surgery.

This machine also has a set of specific programs for athletic preparation in the most important sports disciplines.
The equipment is completed by a complete range of treatments for body care with purely aesthetic purposes.

8 DIFFERENT TYPES OF CURRENT

The Genesy 3000 in particular is distinguished by the possibility of providing all the main medical currents:
EMS currents (Electro Muscle Stimulation)
TENS currents (Trans Cutaneus Nerve Stimulation)
MENS current (Micro Current Stimulation)
Kotz currents with sine wave
Currents Interferenziali
Triangular and Trapezoidal wave currents for M. Denervate
Direct Current for Ionophoresis

9 AREAS OF APPLICATION

The technologies used are the most advanced and allow an extremely easy and safe use of the stimulator in every therapeutic situation.

Functional Rehabilitation (EMS and MENS),
Pain therapy (TENS and MENS),
Endorphic Antalgic Therapy (TENS and MENS)
Diagnosis and Treatment of Denervate Muscle Paralysis
Rehabilitation treatments (Kotz and Interferences)
Deep Pharmacological Treatment (Ionophoresis)
High Level Sports Training (EMS)
Fitness preparation (EMS)
Beauty treatments (EMS, MENS).

 

  • Display Visible area size 2,6”
  • Channels 4 indipendent (8 electrodes)
  • Frequency 0,3-150Hz *
  • Pulse amplitude 40-450µs *
  • Power 0-120mA per channel
  • Power supply – Mains - Rechargeable batteries
  • Size mm 170x220x60
  • Weight gr 1152

 

  • 1 Bag
  • 1 GENESY 3000 stimulator
  • 4 Cables for electrode connection
  • 2 Cables for microcurrents and ionophoresis
  • 4 Self-adhesive square electrodes
  • 4 Self-adhesive rectangular electrodes
  • 2 Iono electrodes + 2 elastic bands
  • 1 Power supply unit
  • 1 Operating manual

Rehab

Rehabilitation programs use EMS currents to restore normal muscle efficiency conditions in post-injury recovery treatments.

Muscle stimulation is also useful in certain situations where normal neuromuscular function is impaired.

Atrophy Recovery, Point Finder Pen, Regrowth, Strengthening, Mobilization, Agonist/Antagonist, Stretch Leg. Cruciate, Achilles tendon stretch, Elastic ligaments limbs sup. , Upper limb hemiplegia, Lower limb hemiplegia, Bladder instability, Mixed incontinence, Stress incontinence, Paraplegia (injury prevention), Upper limb spasticity, Lower limb spasticity, Hip prosthesis

Tens

Transcutaneous Electrical Nerve Stimulation. Transcutaneous electrical stimulation (TENS) is an antalgic stimulation that is performed with impulses that reach the peripheral nervous system through electrodes positioned on the area to be treated. The TENS stimulation is performed with symmetrical biphasic pulses and with frequencies that can vary from 8 to 200 Hz.

Tens Endorfinica, Hematomas, Contractures, Sciatalgia, Antistress, Low back pain, Cervical-brachial neuralgia, Cervical, Scapolo-humeral periarthritis, Epicondylitis, Nausea, Carpal tunnel, Hip osteoarthritis, Chondritis rotulea, Menstrual pain, Intense menstrual pain, Tens Antalgico acute pain, Tens Antalgico chronic pain, Tens Modulata, Deep effusion, Trapezialgia, Hip pain, Knee pain, Ankle pain Tens antal. anti - accommodation, Fracture pain, Chronic pain, Rib fracture, Algodistrophy, Finger pain, Periostite, Cervical rhizopathy, Phantom limb 1-2, Compression spine

Mens (MCR)

MENS currents use currents whose intensity is between 10 and 500 µa (microampere, or one millionth of an ampere).

Normally, MENS therapy involves two distinct phases, the first of which aims to reduce the painful sensation perceived by the patient, while the second phase promotes protein and ATP synthesis by accelerating tissue repair processes.

Epicondylitis, Scapolo-humeral periarthritis, Contractures, Muscle stretching, Muscle tearing, Muscle energy recovery, Contusion, Rheumatoid arthritis, Edema, Herpes Zoster, Hematoma, Ischemic skin ulcer, Sciatalgia, Femoral neuralgia, Lumbago, Disc herniation and lumbar spondylosis, Brachial neuralgia, Stiff neck, Migraine, Neck pain "whiplash", Cervical spondylosis, Shoulder sprain, Carpal tunnel syndrome, Hand arthritis, Finger fracture, Knee sprain, Inflammation of the patellar tendon, osteoarthritis of the knee, ankle sprain, inflammation of the Achilles tendon, microlifting effect of the breast, microlifting effect of the décolleté, microlifting effect of the face, skin elasticity of the face.

Interferential

This particular type of current is called interference because it creates an area of interference within the tissues where the fields intersect. The interference current is a medium frequency alternating sinusoidal current (2500 Hz - 4000 Hz - 10000 Hz), modulated in amplitude, characterized by a high capacity of penetration in the tissues and excellent tolerability even by patients particularly sensitive.

Constant (for painful tendineal and muscular pathologies), Sweep 80 - 100 Hz (for painful tendineal and muscular pathologies) in acute phase, Sweep 5 - 100 Hz (for painful tendineal and muscular pathologies in acute phase and in presence of inflammations), Sweep 5 - 20 Hz (painful manifestations where edema reabsorption is required (pump effect), Multi freq (edema reabsorption in presence of acute pain), Sweep 5 - 50 Hz (for muscular pathologies with need of edema reabsorption), Sweep 50 - 100 Hz (acute and chronic muscular pain), LP (used as an alternative to diapynamic Lps ), CP (used as an alternative to diapynamic Lps ), COST, LP, CP (Association of previous programs), AMF (Suitable for large pain zones), Degenerative knee arthritis, Acromial bursitis, Myocatensive headache. , Acute cervical brachial pain, Coxarthritis, Knee sprain, Acute cervical pain, Acute dorsalgia, Epicondylitis, Chronic lumbago, Scapular - humeral periarthritis, Contractures, Shoulder sprain, Ankle sprain

Kotz

The Kotz current is used in the medical field because it produces a good muscle recruitment and achieves a deeper action than other excitotomotor currents.

The effect of the Kotz current is in fact realized in the deeper layers of the muscles because the skin opposes to this type of current a lesser resistance.

Residual suffering hypotrophy L5, anterior quadriceps rectal hypotrophy, post-traumatic ischio-crural hypotrophy, post-traumatic deltoid hypotrophy, tricipital hypotrophy, medial broad hypotrophy, chronic lumbago, muscle reinforcement after menifucia, vertebral osteoporosis, Flat Foot, Lumbar Vertebral Fracture, Quadriceps, Advanced Muscle Reactivation, Hypokinetic Syndrome, Metatarsalagia, Mid-gluteal Reactivation, Toothed Muscle Reinforcement, Isometric Quadriceps Reinforcement, Periony Muscle Reinforcement, Warm-up, scoliosis, muscle toning, thoracic hyperkyphosis. , Muscular hyperirophylization, Hypotrophiia muscles para vertebral dorsal, Muscular training, Coxarthrosis inveterata gluteal hypotrophy, Defaticamento, Gluteal deficit from suffering, Colles fracture - reactivation flexsori.

Muscoli Denervati

The stimulation of a denervate muscle differs from that of a healthy muscle by the fact that the activation of muscle fibers needs particular currents.

In the presence of a traumatic lesion of the peripheral nerves, the measurement of the chronicles allows to determine if the denervation is poor, partial or total.

1a - Pulse shape Rectangular 1

1b - Pulse shape Rectangular 2

1c - Pulse shape Rectangular 3

2nd - Triangular pulse form 1

2b - Triangular pulse form 2

2c - Triangular pulse form 3

3a - Trapezoidal pulse form 1

3b - Trapezoidal pulse form 2

3c - Trapezoidal pulse form 3

Ionophoresis

The ionophoresis program acts by conveying pharmacological substances inside the tissues thanks to a one-way continuous electric current.

The ions of the medicinal substance are transported inside the body through the cutaneous zones that oppose low resistance to the current, thus reaching the cell membranes.

 Aesthetic

The Genesy 3000 has an endowment of programs designed for body care and beauty: there are numerous specific treatments such as drainage, modeling, lipolysis, facial toning, anti-cellulite actions that can be applied individually or in combination with each other.

The effect of stimulation is in fact enhanced if you combine several treatments together in each session: each phase of treatment in fact acts with different and specific modes (for example: surface massage-drainage-deep massage-anti-cellulite action, toning) which, acting in synergy between them, give you the best and most lasting results.

Bio-pulse drainage, *Lipolysis 1-2, *Relaxation massage, *Toning massage 1-2, *Energy massage 1-2, *Connective massage 1-2, Post-partum drainage, Post-partum lipolysis, Post-partum firming, Breast firming, Breast modeling, *Swollen arms, *Face capillarization, *Face lift effect, *Arterial insufficiency, *Venous insufficiency, *Definition 1-2, *Line 1-2, *Vascularity 1-2 (* = Present programme for both men and women)

 Sport

The Genesy 3000 offers a range of sports training programs to meet the training needs of high-level athletes in major sports disciplines.

*Heating, *Pre-race Heating, *Active Recovery, *Maximum Force 1-2, *Resistant Force 1-2, *Explosive Force 1-2, *Aerobic Resistance 1-2,*Reactivity, *Post-race Recovery, *Decontracting, *Hypertrophy, *Dynamic Work 1-2 (* = Programme for both men and women)

 Fitness

*Firming, *Bio-pulse Firming, Modeling, *Bio-pulse Modeling, *Toning, *Increase Mass, *Body Sculpting, *Definition, *Jogging, *Anaerobic, *Muscle Initiation, *Aerobic, *Cramp Prevention

 

Note: * indicates that both the Men’s and Women’s programmes are present (* = Men’s and Women’s programmes)

The use of electrostimulators is not recommended in the following cases:

- Anterior neck stimulation (carotid sinus).

- Patient peace maker.

- Cancer patients (consult your oncologist).

- Stimulation of the brain region.

- Use on pain whose aetiology is unknown.

- Dermatological sores and diseases.

- acute trauma.

- Stimulation on recent scars.

- Pregnancy.

- The use of electrostimulation in the ocular and genital area is strictly prohibited.

- Use of electrostimulator in water

- In the vicinity of areas to be treated with metallic synthesis and infra-tissue metals (such as prostheses, osteosynthesis materials, spirals, screws, plates), if monophasic currents such as interference and direct current are used (ionophoresis).

 

In case of doubts or concerns, contact your doctor.

Comments (0)