Globus Cycling Pro - Stimulator for Cyclists Who Love Feeling Well

Globus Cycling Pro - Electrostimulator

Globus offers cyclists who love to feel fit cycling pro, a simple and effective electrostimulator, a valid help for your workouts.


€389.00
In stock
G4230

Quantity


Advantages by purchasing this product:

    • Feel good and fit on the pedals!
    • Wide range of programmes
    • Specific programs for road cycling
    • Specific programs for mountain biking
    • Ease of use
    • Immediate and intuitive display
    • Multifunctional
    • Reliable and recognised brand

Globus Cycling Pro - Stimulator for Cyclists Who Love Feeling Well

Use this form to request us information about this product. For more complete answers, please ask detailed questions. Thank You.


  SHIPPING PARTNER

DHL

  SHIPPING PARTNER

DHL

  Monday - Friday:

9.00 - 12.30 | 14.00 - 17.00

Accessories

Check items to add to the cart

Feel good and fit on the pedals!

made in italy

PHYSICAL TRAINING AREA

34 programs to improve the muscular qualities of the cyclist, taking into account the specific needs of those who practice road cycling or mountain biking.

The main objectives of this section are:

  •  increase strength and allow to direct the work of the muscle fibers to the specialty practiced
  • prevent and reduce the risk of joint traumas and muscle injuries
  • allow the cyclist to better withstand long bike rides
  • improve the specific strength and thus the ability of a spurt and sprint, as well as the ability of endurance strength, and necessary for example to tackle climbs
  • provide specific trainings for the upper limbs, especially for those who practice mountain biking and are subjected to continuous vibrations of the handlebars

PAIN-INJURIES AREA

4 programs to treat the traumas and the recurring ailments in cycling. Specific protocols are included to:

  •  relieve muscle tension on the cervical area and the shoulders
  • promote recovery after lesions and muscle contractures
  • relieve muscle and joint back pains
  • treat knee inflammations

 

RECOVERY AREA

6 programs dedicated to relax and loosen the tired muscles. In particular these programs aim to:

  •  relieve the contracted muscle at the end of the training and/or competition
  • speed recovery between two sessions if you practiced competitions or stage races
  • give relief to the neck and shoulders when they are particularly tense because of the hours spent in the saddle

 PREVENTION AREA

2 programs aimed to drastically reduce the number of injuries and the main musculoskeletal ailments of the cyclist. In particular these programs aim to:

  • stabilize the patella to prevent knee inflammation
  • strengthen the abdominal muscles to prevent lumbagos



ADVANCED TECHNOLOGIES IN THE NEW 2016 RANGE

Globus presents an innovative technology intended to revolutionize the electrostimulation application in beauty, sport and medical fields: 3S (Serial Sequential Stimulation) technology.

“3S” SERIAL SEQUENTIAL STIMULATION: The sequential contraction of the different muscular groups produces a deep pressure wave in the musculature involved causing the interstitial fluid drainage and enhancing the return of the venous blood to the heart. It is useful also in sport field for warm-down and post-competition active recovery, especially in endurance sports such as running, cross-country, skiing, bike-riding, triathlon etc.

ACTION NOW: it enables to activate the muscular contraction through an external control managed by an operator. In this way it is possible to link the stimulation to the voluntary contraction to obtain a greater recruitment of the muscular fibers and an important coordinating effect.

SPECIAL SPORTS: a special program list to stimulate in an effective and specific manner the muscular areas used in the more common sport activities.

SPECIAL FUNCTIONS

MULTI-useR: it permits to store up to 25 different users and to create a library of personalized programs depending on individual aims.

SYNCROSTIM: It is possible to increase the intensity of the 4 channels simultaneously using only one button.

RUN TIME FUNCTION: this function permits to modify the time, the frequency and the pulse amplitude during the treatment.

AUTOMATIC MODE (AUTO STIM®): it permits to execute a program in automatic mode with no need of intervening manually in the intensity regulation.

PROGRAMMABLE: 15 free memories, only for EMS and TENS.

2+2 MODE: it permits to execute two different programs simultaneously.

FAVORITES: it permits to store up to 25 programs for each user.

LAST 10: it stores the last 10 executed programs.

WORKING TIME: It stores the total usage time of the device.

MY TRAINER: it shows the electrode position on the display.

STIM LOCK

GRAPHIC DISPLAY

  • Channels: 4 independent CHANNELS
  • Frequency: 0.3 - 150 Hz
  • Power: 120 mA per channel
  • Pulse width: 40 - 450 μs
  • Waveform: square, biphasic, symmetric, compensated wave
  • Power supply: rechargeable battery
  • Backlit display
  • Device in Class II A
  • Complies with Directive 93/42/EEC-2007/47/EEC
  • 1 Stock exchange
  • 1 GLOBUS "Cycling Pro" stimulator
  • 4 Cables for electrode connection
  • 2 Cables for microcurrents and iontophoresis
  • 4 Square self-adhesive electrodes
  • 4 Self-adhesive rectangular electrodes
  • 1 Charger
  • 1 Operation manual

The proposed programmes were divided into four areas concerning physical preparation for cyclists.

 PHYSICAL PREPARATION AREA

  • 34 programs to improve the muscular qualities of the cyclist who practices road sports, or via Mountain Bike, off-road.
  • The main objectives are:
  • Allow the rider to better withstand long bike rides
  • Increase strength and allow to orient the work of muscle fibers on specific areas
  • Prevent and reduce the risk of joint trauma or muscle injury
  • Improve the specific force, then stretch, sprint and resistant, suitable to face for example the climbs
  • Provide specific workouts for the upper limbs, especially for those who practice mountain biking and is subjected to the constant vibration of the handlebars

 PAIN AND INJURY AREA  

4 programs to treat recurrent injuries and discomforts in cycling.

Specific protocols for:

  • Dissolve muscle tension on the cervical area and shoulders
  • Promote recovery after injuries and muscle contractures
  • Relieve muscle-joint pain in the back
  • Treat inflammation of the knee

RECOVERY AREA  

6 programs dedicated to relaxing and relaxing tired muscles. 

The main objectives are:

  • dissolve the contracted and sore muscles at the end of workouts/ races
  • speed up the recovery and disposal of fatigue between one session and another if you practice races or tours in stages
  • give relief to the neck and shoulders when they are particularly tesia because of the hours spent in the saddle

 PREVENTION AREA

2 programs aimed at drastically reducing the number of injuries and major musculoskeletal disorders of the cyclist.

The main objectives are: 

  • stabilize the patella to prevent knee inflammation
  • strengthen abdominal muscles to prevent low back pain

The programs can be divided into areas of the body, ensuring in this very specific and customized according to the muscle to be stimulated. 

Road physical preparation

  • Capillarization
  • Force
  • Strength
  • Aerobic endurance
  • Agonist-antagonist
  • Special sprint

Physical preparation Mountain biking

  • Capillarization
  • Force
  • Strength
  • Explosive force
  • Agonist-antagonist
  • Aerobic endurance
  • Resistance to fast force
  • Fartlek

 Prevention

  • Back pain
  • Knee

 Pain-injuries

  • Cervical pain
  • Back pain
  • Muscular contractures
  • Knee inflammation

Retrieval

  • Decontracting
  • Cooling off post. training

We do not recommend the use of electrostimulators in the following cases:

  • Stimulation of the front part of the neck (carotid sinus).
  • Patient peacemaker carrier.
  • Cancer patients (consult your oncologist).
  • Stimulation of the brain region.
  • Use on pains of which the etiology is not known.
  • Sores and dermatological pathologies.
  • Acute trauma.
  • Stimulation on recent scars.
  • Pregnancy.
  • It is absolutely forbidden to use the electrostimulator in the ocular and genital area.
  • Use of the electrostimulator in water
  • In the vicinity of areas to be treated characterised by the presence of metallic synthesis media and infra-tissue metals (such as prostheses, osteosynthesis materials, spirals, screws, plaques), if monophasic currents such as interference and direct current (iontophoresis) are used.

In case of doubts or concerns, contact your doctor.

 The professional who purchases and uses equipment for professional purposes is directly responsible for it legally and criminally. In particular, please note that the professional use of equipment by beauticians, is regulated by Ministerial Decree Law 1/90. Therefore, before purchasing, we invite you to read the Decree and the technical data sheets of the permitted equipment contained therein.

Comments (0)