I-Tech Mio Care Fitness - Muscle Stimulator Beauty and Fitness

Muscle Stimulator I Tech Mio Care Fitness

2 Channel Electrostimulator With 8 Application Points, 55 Programs, Over 500 Application Modes. Beauty, Fitness, Rehabilitation and Pain Treatments. Internal rechargeable batteries included.


€189.00
In stock
10003

Quantity


Advantages by purchasing this product:

    • Large budget of Programmes
    • Maximum Ease of use
    • Simple and immediate display
    • Visible and fast results
    • Multifunctional and Multidisciplinary
    • Brand Reliable and Known

I-Tech Mio Care Fitness - Muscle Stimulator Beauty and Fitness

Use this form to request us information about this product. For more complete answers, please ask detailed questions. Thank You.


  SHIPPING PARTNER

DHL

  SHIPPING PARTNER

DHL

  Monday - Friday:

9.00 - 12.30 | 14.00 - 17.00

Accessories

Check items to add to the cart

My Care Fitness Pain Treatment Device, Effective And Simple To Use!

My-Care FITNESS is a proper muscle stimulator for the demands of all the components of the family. It condenses in fact in reduced dimensions the technology of the most advanced equipments electromedical. It is able to produce impulses for pain therapy and muscular thickening, the lipolisi.

My-Care FITNESS produces alternate impulses around two channels so that to produce contractions or sequential (agonist-antagonist) stimulations. The sporting programs are able to train different fibers muscular (lens or rapidses) and different characteristics of the strength (speed, explosiveness, rapidity); other useful programs to the sportsman are resistance, massage and recovery after competition

The reduced dimension however you/he/she must not deceive: be able in fact to develop enough intensity of impulse to contract the muscles of the legs of a bodybuilder! The muscle stimulator is programmed according to the more recognized protocols of elettrostimollation alternating periods of muscular contraction to tall periods frequency (40 - 120 Hz) of low frequency of recovery (2-6 Hz). In an only instrument to 2 channels you/he/she has been possible to condense the greatest part of the treatments of known elettrostimulation.

 

 

  • Number of output channels: 2
  • Type of current: EMS, TENS, microcurrent
  • Waveform: rectangular symmetrical plywood
  • Application points (electrodes): 8
  • Power supply: internal rechargeable batteries
  • Programs: 55
  • Connection type (accessories): plug
  • Applications for body: yes
  • Applications for face: yes
  • Dimensions: 60 X 135 X 19 mm
  • TENS and EMS electrotherapy with graphic display
  • 2 electrode connection cables with 4 leads (total 8 pluggable electrodes)
  • 1 square electrode bag
  • 1 bag rectangular electrodes
  • Ni-Mh rechargeable internal battery with new technology LL (long-lasting) low self-discharge
  • Charger
  • Fastening clip to the belt
  • Carrying bag

Aesthetics (Beauty)

  • 01 - Upper limb firming and
  • 02 - Firming of the lower limbs
  • 03 - Upper limb toning and
  • 04 - Toning of the lower limbs
  • 05 - Definition of upper limbs and trunk
  • 06 - Definition of lower limbs
  • 07 - Modelling
  • 08 - Microlifting
  • 09 - Lipolysis abdomen
  • 10 - Lipolysis of the thighs
  • 11 - Lipolysis of buttocks and hips
  • 12 - Lipolysis of the arms
  • 13 - Tissue elasticity
  • 14 - Capillarisation
  • 15 - Heaviness in the legs

Pain (TENS)

  • 01 - Conventional Tens (fast)
  • 02 - Tens endorphinic (delayed)
  • 03 - Tens to maximum values
  • 04 - Anti-inflammatory
  • 05 - Cervicalgia/mytensive headache
  • 06 - Back pain/sciatica
  • 07 - Sprains/bruises
  • 08 - Vascularity
  • 09 - Decontracting
  • 10 - Bruises
  • 11 - Prevention of atrophy
  • 12 - Atrophy (trophism recovery)
  • 13 - Hand and wrist pain
  • 14 - Foot stimulation
  • 15 - Epicondylitis
  • 16 - Epitrocleite
  • 17 - Periarthritis
  • 18 - Microcurrent
  • 19 - Stress incontinence
  • 20 - Urgency incontinence

Fitness

  • 01 - Heating
  • 02 - Upper limb and trunk resistance
  • 03 - Lower limb resistance
  • 04 - Strength resistant upper limbs and trunk
  • 05 - Strength resistant lower limbs
  • 06 - Basic strength upper limbs and trunk
  • 07 - Base force lower limbs
  • 08 - Fast force upper limbs and trunk
  • 09 - Fast force lower limbs
  • 10 - Explosive force upper limbs and trunk
  • 11 - Explosive force lower limbs
  • 12 - Deep capillarization
  • 13 - Muscle recovery
  • 14 - Agonist-antagonist
  • 15 - Sequential tonic contractions a.s. and t.
  • 16 - Sequential tonic contractions a.i.
  • 17 - Sequential phasic contractions a.s. and t.
  • 18 - Sequential phasic contractions a.i.
  • 19 - Decontracting
  • 20 - Deep massage

We do not recommend the use of electrostimulators in the following cases:

  • Stimulation of the front part of the neck (carotid sinus).
  • Patient peacemaker carrier.
  • Cancer patients (consult your oncologist).
  • Stimulation of the brain region.
  • Use on pains of which the etiology is not known.
  • Sores and dermatological pathologies.
  • Acute trauma.
  • Stimulation on recent scars.
  • Pregnancy.
  • It is absolutely forbidden to use the electrostimulator in the ocular and genital area.
  • Use of the electrostimulator in water
  • In the vicinity of areas to be treated characterised by the presence of metallic synthesis media and infra-tissue metals (such as prostheses, osteosynthesis materials, spirals, screws, plaques), if monophasic currents such as interference and direct current (iontophoresis) are used.

In case of doubts or concerns, contact your doctor.

PROFESSIONAL USE: The professional who buys and uses equipment for professional purposes, is directly responsible legally and criminally. In particular, please note that the professional use of equipment by beauticians, is regulated by Ministerial Decree Law 1/90. Therefore, before purchasing, we invite you to read the Decree and the technical data sheets of the permitted equipment contained therein.